Please use this identifier to cite or link to this item: https://cuir.car.chula.ac.th/handle/123456789/17485
Full metadata record
DC FieldValueLanguage
dc.contributor.authorNatthaporn Tanpowpong-
dc.contributor.authorSudarat Yimpraphan-
dc.contributor.authorLaddawan Vajragupta-
dc.contributor.authorBoonchu Sirijindakul-
dc.contributor.authorBunthoon Nunthasoot-
dc.contributor.otherChulalongkorn University. Department of Radiology-
dc.contributor.otherChulalongkorn University. Department of Radiology-
dc.contributor.otherChulalongkorn University. Faculty of Medicine-
dc.contributor.otherChulalongkorn University. Department of Surgery-
dc.contributor.otherChulalongkorn University. Department of Surgery-
dc.date.accessioned2012-03-08T03:14:11Z-
dc.date.available2012-03-08T03:14:11Z-
dc.date.issued2007-
dc.identifier.citationAsian biomedicine : research, reviews and news. 1,4(December 2007): 415-420en
dc.identifier.issn1905-7415-
dc.identifier.urihttp://cuir.car.chula.ac.th/handle/123456789/17485-
dc.description.abstractBackground: Measurement of liver volume has been used in planning radiotherapy dosimetry, assessing the progressiveness of various diseases and measuring the response to treatment. Objective: To measure liver volume using multidetector computed tomography (MDCT), and to evaluate the accuracy and inter-observer reliability of liver volume measurement using MDCT. Methods: Measurements were done using a track-ball to draw its outline manually, and calculate by summation of each slice volume which was measured in 8 mm thickness. The calculated liver volume was compared to the actual liver volume which was measured by water replacement. Results and conclusion: There was a strong correlation between the calculated and actual liver volumes performed by a radiologist and a technician (98.0 % and 97.1 % agreement, respectively). High observer reliability was identified (99.2 % agreement). This technique can be easily used by well-trained personnel such as radiologists or technicians.en
dc.format.extent301610 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoenes
dc.publisherChulalongkorn Universityen
dc.rightsChulalongkorn Universityen
dc.subjectLiveren
dc.subjectTomographyen
dc.titleAccuracy of liver volume measurement using multidetector computed tomographyen
dc.typeArticlees
dc.email.authorNo information provided-
dc.email.authorNo information provided-
dc.email.authorNo information provided-
dc.email.authorNo information provided-
dc.email.author[email protected]-
dc.subject.keywordLiver volumeen
dc.subject.keywordMeasurementen
Appears in Collections:Med - Journal Articles

Files in This Item:
File Description SizeFormat 
article10.pdf294.54 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.