Please use this identifier to cite or link to this item:
https://cuir.car.chula.ac.th/handle/123456789/17485
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Natthaporn Tanpowpong | - |
dc.contributor.author | Sudarat Yimpraphan | - |
dc.contributor.author | Laddawan Vajragupta | - |
dc.contributor.author | Boonchu Sirijindakul | - |
dc.contributor.author | Bunthoon Nunthasoot | - |
dc.contributor.other | Chulalongkorn University. Department of Radiology | - |
dc.contributor.other | Chulalongkorn University. Department of Radiology | - |
dc.contributor.other | Chulalongkorn University. Faculty of Medicine | - |
dc.contributor.other | Chulalongkorn University. Department of Surgery | - |
dc.contributor.other | Chulalongkorn University. Department of Surgery | - |
dc.date.accessioned | 2012-03-08T03:14:11Z | - |
dc.date.available | 2012-03-08T03:14:11Z | - |
dc.date.issued | 2007 | - |
dc.identifier.citation | Asian biomedicine : research, reviews and news. 1,4(December 2007): 415-420 | en |
dc.identifier.issn | 1905-7415 | - |
dc.identifier.uri | http://cuir.car.chula.ac.th/handle/123456789/17485 | - |
dc.description.abstract | Background: Measurement of liver volume has been used in planning radiotherapy dosimetry, assessing the progressiveness of various diseases and measuring the response to treatment. Objective: To measure liver volume using multidetector computed tomography (MDCT), and to evaluate the accuracy and inter-observer reliability of liver volume measurement using MDCT. Methods: Measurements were done using a track-ball to draw its outline manually, and calculate by summation of each slice volume which was measured in 8 mm thickness. The calculated liver volume was compared to the actual liver volume which was measured by water replacement. Results and conclusion: There was a strong correlation between the calculated and actual liver volumes performed by a radiologist and a technician (98.0 % and 97.1 % agreement, respectively). High observer reliability was identified (99.2 % agreement). This technique can be easily used by well-trained personnel such as radiologists or technicians. | en |
dc.format.extent | 301610 bytes | - |
dc.format.mimetype | application/pdf | - |
dc.language.iso | en | es |
dc.publisher | Chulalongkorn University | en |
dc.rights | Chulalongkorn University | en |
dc.subject | Liver | en |
dc.subject | Tomography | en |
dc.title | Accuracy of liver volume measurement using multidetector computed tomography | en |
dc.type | Article | es |
dc.email.author | No information provided | - |
dc.email.author | No information provided | - |
dc.email.author | No information provided | - |
dc.email.author | No information provided | - |
dc.email.author | [email protected] | - |
dc.subject.keyword | Liver volume | en |
dc.subject.keyword | Measurement | en |
Appears in Collections: | Med - Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
article10.pdf | 294.54 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.